Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 12(8)2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-36010215

RESUMO

Pelizaeus−Merzbacher disease (PMD) is an X-linked recessive disorder of the central nervous system. We performed 7 Tesla magnetic resonance imaging of the brain in Tama rats, a rodent PMD model, and control rats, as well as evaluated the diagnostic values. In the white matter of the Tama rats, the T2 values were prolonged, which is similar to that observed in patients with PMD (60.7 ± 1.8 ms vs. 51.6 ± 1.3 ms, p < 0.0001). The apparent diffusion coefficient values in the white matter of the Tama rats were higher than those of the control rats (0.68 ± 0.03 × 10−3 mm2/s vs. 0.64 ± 0.03 × 10−3 mm2/s, p < 0.05). In proton magnetic resonance spectroscopy, the N-acetylaspartate (6.97 ± 0.12 mM vs. 5.98 ± 0.25 mM, p < 0.01) and N-acetylaspartate + N-acetylaspartylglutamate values of the Tama rats were higher (8.22 ± 0.17 mM vs. 7.14 ± 0.35 mM, p < 0.01) than those of the control rats. The glycerophosphocholine + phosphocholine values of the Tama rats were lower than those of the control rats (1.04 ± 0.09 mM vs. 1.45 ± 0.04 mM, p < 0.001). By using Luxol fast blue staining, we confirmed dysmyelination in the Tama rats. These results are similar to those of patients with PMD and other PMD animal models.

2.
Front Neurosci ; 16: 921922, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35812224

RESUMO

Background: The unsurpassed sensitivity of intracranial electroencephalography (icEEG) and the growing interest in understanding human brain networks and ongoing activities in health and disease have make the simultaneous icEEG and functional magnetic resonance imaging acquisition (icEEG-fMRI) an attractive investigation tool. However, safety remains a crucial consideration, particularly due to the impact of the specific characteristics of icEEG and MRI technologies that were safe when used separately but may risk health when combined. Using a clinical 3-T scanner with body transmit and head-receive coils, we assessed the safety and feasibility of our icEEG-fMRI protocol. Methods: Using platinum and platinum-iridium grid and depth electrodes implanted in a custom-made acrylic-gel phantom, we assessed safety by focusing on three factors. First, we measured radio frequency (RF)-induced heating of the electrodes during fast spin echo (FSE, as a control) and the three sequences in our icEEG-fMRI protocol. Heating was evaluated with electrodes placed orthogonal or parallel to the static magnetic field. Using the configuration with the greatest heating observed, we then measured the total heating induced in our protocol, which is a continuous 70-min icEEG-fMRI session comprising localizer, echo-planar imaging (EPI), and magnetization-prepared rapid gradient-echo sequences. Second, we measured the gradient switching-induced voltage using configurations mimicking electrode implantation in the frontal and temporal lobes. Third, we assessed the gradient switching-induced electrode movement by direct visual detection and image analyses. Results: On average, RF-induced local heating on the icEEG electrode contacts tested were greater in the orthogonal than parallel configuration, with a maximum increase of 0.2°C during EPI and 1.9°C during FSE. The total local heating was below the 1°C safety limit across all contacts tested during the 70-min icEEG-fMRI session. The induced voltage was within the 100-mV safety limit regardless of the configuration. No gradient switching-induced electrode displacement was observed. Conclusion: We provide evidence that the additional health risks associated with heating, neuronal stimulation, or device movement are low when acquiring fMRI at 3 T in the presence of clinical icEEG electrodes under the conditions reported in this study. High specific absorption ratio sequences such as FSE should be avoided to prevent potential inadvertent tissue heating.

3.
Dev Biol ; 443(2): 127-136, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-30213538

RESUMO

Newts have remarkable ability to regenerate their organs and have been used in research for centuries. However, the laborious work of breeding has hampered reverse genetics strategies in newt. Here, we present simple and efficient gene knockout using Cas9 ribonucleoprotein complex (RNP) in Pleurodeles waltl, a species suitable for regenerative biology studies using reverse genetics. Most of the founders exhibited severe phenotypes against each target gene (tyrosinase, pax6, tbx5); notably, all tyrosinase Cas9 RNP-injected embryos showed complete albinism. Moreover, amplicon sequencing analysis of Cas9 RNP-injected embryos revealed virtually complete biallelic disruption at target loci in founders, allowing direct phenotype analysis in the F0 generation. In addition, we demonstrated the generation of tyrosinase null F1 offspring within a year. Finally, we expanded this approach to the analysis of noncoding regulatory elements by targeting limb-specific enhancer of sonic hedgehog, known as the zone of polarizing activity regulatory sequence (ZRS; also called MFCS1). Disruption of ZRS led to digit deformation in limb regeneration. From these results, we are confident that this highly efficient gene knockout method will accelerate gene functional analysis in the post-genome era of salamanders.


Assuntos
Proteína 9 Associada à CRISPR/genética , Pleurodeles/genética , Regeneração/genética , Animais , Animais Geneticamente Modificados , Cruzamento/métodos , Proteína 9 Associada à CRISPR/metabolismo , Sistemas CRISPR-Cas , Biologia do Desenvolvimento/métodos , Técnicas de Inativação de Genes , Fenótipo , Pleurodeles/metabolismo , Ribonucleoproteínas/genética , Ribonucleoproteínas/metabolismo , Análise de Sequência de DNA/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...